第 31 卷第 5 期 |  | Vol. 31 No. 5 | 2001 年 10 月 | Oct 2001 |
|
所屬欄目:分析與測試
1-(2-氯苯基)-5(4H)-四唑啉酮氣相色譜法的分析研究 |
潘忠穩; 姚瓊; 凌冰(安徽省化工研究院) |
摘 要:用 5 %OV - 17,長(cháng)度為 2m的玻璃填充柱 ,以硝基苯為內標物 ,在 140℃柱溫下 ,用FID檢測器對 1 (2 氯苯基 ) 5 (4H ) 四唑啉酮進(jìn)行定量分析。該方法變異系數為0 2 2 % ,平均回收率 99 8% ,線(xiàn)性相關(guān)系數為 0 99998 |
關(guān)鍵詞:氣相色譜法; 1(2氯苯基)5(4H)四唑啉酮; 分析 |
中圖分類(lèi)號:TQ252.8 文獻標識碼:A 文章編號:1009-9212(2001)05-0047-02 |
|
Analysis of 1-(2-Chlorophenyl)-5(4H)-tetrazolinone by Gas Chomatography |
PAN Zhong wen; YAO Qiong; LING Bing (Anhui Research Institute of Chemical Industry; Hefei 230041) |
Abstract:chlorophenyl) 5(4H) tetrazolinone was analyzed by gas chomatography with flame ionization detection on Φ2.5mm×2m 5% OV-17/Gas chromosorb W HP (0.147~0.175mm) packed column. The column temperature was 140℃. The ionization temperature was 240℃ and the detection temperature was 240℃. The linear relationship of this method was very good. The standard deviated and viation coefficient were 0.21% and 0.22% respectively. |
Key words:chlorophenyl) 5(4H) tetrazolinone; analysis; gas chomatography |
|
收稿日期:2001-08-12
|
閱讀全文 |
|